Carrier 38CG024 Manuale Utente

Navigare online o scaricare Manuale Utente per Climatizzatori a split Carrier 38CG024. Carrier 38CG024 Product data Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - Product Data Digest

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons Console Console Condenser & Mulit-Zone

Pagina 2 - Duct-Free Systems Digest

ARI* CapacitiesSatellite ApplicationsIndoor Outdoor Std. Net Cooling Total SEER EER Heating Heating HeatingSection Section CFM BTUH kW High High HighB

Pagina 3 - 01/12/02

System Cross MatchCooling Only High Wall Heat Pump High WallNominal Indoor Indoor Outdoor Outdoor Nominal Indoor Indoor Outdoor OutdoorCapacity Unit U

Pagina 4 - 01/09/02

System Cross MatchCooling Only High Wall Heat Pump High WallNominal Indoor Indoor Outdoor Outdoor Nominal Indoor Indoor Outdoor OutdoorCapacity Unit U

Pagina 5

System & Unit Specifications – Section 11ProductProductCooling Only System SpecificationsHeat Pump System SpecificationsUnit Specifications

Pagina 6

Cooling Only System SpecificationsHigh WallNominal Indoor Outdoor ARI ARI Sound Rating (dBa)Capacity Unit Unit Capacity CFM SEER EER Indoor Indo

Pagina 7

Cooling Only System SpecificationsHigh WallNominal Indoor Outdoor ARI ARI Sound Rating (dBa)Capacity Unit Unit Capacity CFM SEER EER Indoor Indo

Pagina 8 - 09/17/01

Cooling Only System SpecificationsHigh WallNominal Indoor Outdoor ARI ARI Sound Rating (dBa)Capacity Unit Unit Capacity CFM SEER EER Indoor Indo

Pagina 9

Cooling Only System SpecificationsHigh WallNominal Indoor Outdoor ARI ARI Sound Rating (dBa)Capacity Unit Unit Capacity CFM SEER EER Indoor Indo

Pagina 10

Cooling Only System SpecificationsHigh WallNominal Indoor Outdoor ARI ARI Sound Rating (dBa)Capacity Unit Unit Capacity CFM SEER EER Indoor Indo

Pagina 11

Cooling Only System SpecificationsHigh WallNominal Indoor Outdoor ARI ARI Sound Rating (dBa)Capacity Unit Unit Capacity CFM SEER EER Indoor Indo

Pagina 12 - OUTDOOR UNITS

Heat Pump System SpecificationsHigh WallNominal Indoor Outdoor ARI Capacities ARI Sound Rating (dBa)Capacity Unit Unit C/O H/P CFM SEER EER

Pagina 13 - FAN COIL UNITS

APPLICATION DATA 1. Unit selection Select equipment to either match or be slightly less than anticipated peak cooling load. This provides better humi

Pagina 14

Heat Pump System SpecificationsHigh WallNominal Indoor Outdoor ARI Capacities ARI Sound Rating (dBa)Capacity Unit Unit C/O H/P CFM SEER EER

Pagina 15

Heat Pump System SpecificationsHigh WallNominal Indoor Outdoor ARI Capacities ARI Sound Rating (dBa)Capacity Unit Unit C/O H/P CFM SEER EER

Pagina 16

Heat Pump System SpecificationsHigh WallNominal Indoor Outdoor ARI Capacities ARI Sound Rating (dBa)Capacity Unit Unit C/O H/P CFM SEER EER

Pagina 17

Heat Pump System SpecificationsHigh WallNominal Indoor Outdoor ARI Capacities ARI Sound Rating (dBa)Capacity Unit Unit C/O H/P CFM SEER EER

Pagina 18

Heat Pump System SpecificationsHigh WallNominal Indoor Outdoor ARI Capacities ARI Sound Rating (dBa)Capacity Unit Unit C/O H/P CFM SEER EER

Pagina 19

Unit SpecificationsVert Vert Max Tube Connections DimensionsModel Voltage MCA MOCP Lift Drop Tube Liquid Vapor Width H

Pagina 20

Condenser Only Ratings – Section 12ApplicationApplicationHDCHDL

Pagina 21 - 02/15/02

Condenser Only RatingsSST Air Temperature Entering Condenser (F)(F) 55 65 75 85 95 105 115 12538HDC018TCG19.7 18.0 16.4 14.8 13.3 11.8 10.4 9.030 SDT7

Pagina 22

Condenser Only RatingsSST Air Temperature Entering Condenser (F)(F) 55 65 75 85 95 105 115 12538HDC036TCG33.6 32.1 30.5 28.7 25.7 23.1 20.6 18.330 SDT

Pagina 23

38HDL CONDENSER-ONLY RATINGSSee Legend on next page. Click here to view the next page of condenser-only performance data.SST(F)AIR TEMPERATURE ENTERI

Pagina 24

HIGH WALL UNITS — These units should be positioned as high as possible on the wall for best air circulation. Allow adequate clearances above the unit

Pagina 25

38HDL CONDENSER-ONLY RATINGS (cont) LEGENDSST(F)AIR TEMPERATURE ENTERING CONDENSER (F)55 65 75 85 95 105 115 12538HDL0

Pagina 26

Duct Free Systems - Performance Data & Expanded RatingsCooling Only High Wall Heat Pump High WallIndoor Outdoor Net System Indoor Outdoor Net Net

Pagina 27

Performance Data & Expanded Ratings - Systems Index TableMulti Split 4 Ton 38HDS048 Click here to return to System Index Table. I

Pagina 28 - 11/26/01

COOLINGCAPACITIESSYSTEM1*—HIGHWALLSYSTEM(38AN009WITH40QNB009)Temp (F)Air EnteringCondenser(Edb)AirEnteringEvaporator—Cfm/BF184/0.08 200/0.09 215/0.10A

Pagina 29

COOLINGCAPACITIES(cont)SYSTEM2*—HIGHWALLSYSTEM(38AN012WITH40QNB012)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF245/0.12 280/0.14

Pagina 30 - 08/07/00

COOLINGCAPACITIES(cont)SYSTEM3*—HIGHWALLSYSTEM(38HDC018WITH40QNB018)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF360/0.12 414/0.1

Pagina 31

COOLINGCAPACITIES(cont)SYSTEM4*—HIGHWALLSYSTEM(38HDC024WITH40QNB024)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF456/0.04 502/0.0

Pagina 32

COOLINGCAPACITIES(cont)SYSTEM5*—CEILING-SUSPENDEDSYSTEM(38HDC018WITH40QAB024†)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF320/0.

Pagina 33

COOLINGCAPACITIES(cont)SYSTEM6*—CEILING-SUSPENDEDSYSTEM(38HDC024WITH40QAB024)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF400/0.0

Pagina 34

COOLINGCAPACITIES(cont)SYSTEM7*—CEILING-SUSPENDEDSYSTEM(38HDC030WITH40QAB036)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF640/0.0

Pagina 35

FAN COIL UNITS CONDITION 40QN 40QA 40QK 40CG 40CS 40HD Maximum Room Temperature (F) 84 84 95 Min

Pagina 36 - Dimensional Drawing

COOLINGCAPACITIES(cont)SYSTEM8*—CEILING-SUSPENDEDSYSTEM(38HDC036WITH40QAB036)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF640/0.0

Pagina 37

COOLINGCAPACITIES(cont)SYSTEM9*—53QAB048CEILING-SUSPENDEDSYSTEM(38HDC048WITH40QAB048)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/B

Pagina 38 - Part 2 – Products

COOLINGCAPACITIES(cont)SYSTEM10*—CEILING-SUSPENDEDSYSTEM(38HDC060WITH40QAB060)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF1040/0

Pagina 39

COOLINGCAPACITIES(cont)SYSTEM11*—IN-CEILINGCASSETTESYSTEM(38HDC018WITH40QKB024)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF375/0

Pagina 40

COOLINGCAPACITIES(cont)SYSTEM12*—IN-CEILINGCASSETTESYSTEM(38HDC024WITH40QKB036)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF635/0

Pagina 41

COOLINGCAPACITIES(cont)SYSTEM13*—IN-CEILINGCASSETTESYSTEM(38HDC030WITH40QKB036)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF635/0

Pagina 42

COOLINGCAPACITIES(cont)SYSTEM14*—IN-CEILINGCASSETTESYSTEM(38HDC036WITH40QKB036)Temp (F)Air EnteringCondenser(Edb)Air Entering Evaporator — Cfm/BF635/0

Pagina 43

COOLING CAPACITIESSYSTEM 15* – 38HDL018 WITH 40QNB024 LEGEND Rating ConditionNot recommended for long-term operation*Clic

Pagina 44

COOLING CAPACITIES (cont)SYSTEM 16* – 38HDL024 WITH 40QNB024 LEGEND Rating ConditionNot recommended for long-term operation*Click

Pagina 45

COOLING CAPACITIES (cont)SYSTEM 17* – 38HDL018 WITH 40QAB024ƒ LEGEND Rating ConditionNot recommended for long-term operation*Clic

Pagina 46

11.Freshairandducting a. Theceiling-suspendedfancoilunitsmaybringinupto30%freshair.Thepercentageofairallowableiscalculated based on the unit hig

Pagina 47

COOLING CAPACITIES (cont)SYSTEM 18* – 38HDL024 WITH 40QAB024 LEGEND Rating ConditionNot recommended for long-term operati

Pagina 48

COOLING CAPACITIES (cont)SYSTEM 19* – 38HDL030 WITH 40QAB036 LEGEND Rating ConditionNot recommended for long-term operat

Pagina 49

COOLING CAPACITIES (cont)SYSTEM 20* – 38HDL036 WITH 40QAB036 LEGEND Rating ConditionNot recommended for long-term operati

Pagina 50

COOLING CAPACITIES (cont)SYSTEM 21* – 38HDL048 WITH 40QAB048 LEGEND Rating ConditionNot recommended for long-term operat

Pagina 51 - Part 2 – Product

COOLING CAPACITIES (cont)SYSTEM 22* – 38HDL060 WITH 40QAB060 LEGEND Rating ConditionNot recommended for long-term operat

Pagina 52 - 3

COOLING CAPACITIES (cont)SYSTEM 23* – 38HDL018 WITH 40QKB024 LEGEND Rating ConditionNot recommended for long-term operat

Pagina 53

COOLING CAPACITIES (cont)SYSTEM 24* – 38HDL024 WITH 40QKB036 LEGEND Rating ConditionNot recommended for long-term operat

Pagina 54

COOLING CAPACITIES (cont)SYSTEM 25* – 38HDL030 WITH 40QKB036 LEGENDRating ConditionNot recommended for long-term operati

Pagina 55

COOLING CAPACITIES (cont)SYSTEM 26* – 38HDL036 WITH 40QKB036 LEGEND Rating ConditionNot recommended for long-term operat

Pagina 56

COOLINGCAPACITIESSYSTEM27C*—HIGHWALLSYSTEM(38BK009WITH40QNE009)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM/BF214/0.10 233/0.11

Pagina 57

Duct Free Systems - Electrical Data - 40 Series High Wall Units Model Voltage Voltage Fan Heater Power MinimumV-Ph-60Hz Min Max FLA k

Pagina 58

COOLINGCAPACITIES(cont)SYSTEM28C*—HIGHWALLSYSTEM(38BK012WITH40QNE012)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM/BF245/0.12 28

Pagina 59

COOLINGCAPACITIES(cont)SYSTEM29C*—HIGHWALLSYSTEM(38BK018WITH40QNE018)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM/BF376/0.14 40

Pagina 60

COOLINGCAPACITIES(cont)SYSTEM30C*—HIGHWALLSYSTEM(38BK024WITH40QNE024)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM/BF446/0.04 48

Pagina 61

COOLINGCAPACITIES(cont)SYSTEM31C*—CEILING-SUSPENDEDSYSTEM(38QR-C018WITH40QAE024)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM/BF

Pagina 62

COOLINGCAPACITIES(cont)SYSTEM32C*—CEILING-SUSPENDEDSYSTEM(38QR-C024WITH 40QAE024)TEMP (F)AIR ENTERNGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM

Pagina 63

COOLINGCAPACITIES(cont)SYSTEM33C*—CEILING-SUSPENDEDSYSTEM(38QR-C030WITH40QAE036)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM/BF

Pagina 64

COOLINGCAPACITIES(cont)SYSTEM34C*—CEILING-SUSPENDEDSYSTEM(38QR-C036SINGLE-PHASEUNITWITH40QAE036)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDO

Pagina 65

COOLINGCAPACITIES(cont)SYSTEM35C*—CEILING-SUSPENDEDSYSTEM(38QR-C0363-PHASEUNITWITH40QAE036)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UN

Pagina 66

COOLINGCAPACITIES(cont)SYSTEM36C*—CEILING-SUSPENDEDSYSTEM(38QR-C048WITH40QAE048)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM/BF

Pagina 67

COOLINGCAPACITIES(cont)SYSTEM37C*—CEILING-SUSPENDEDSYSTEM(38QR-C060WITH40QAE060)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM/BF

Pagina 68

Duct Free Systems - Electrical Data - 40 Series Under Ceiling UnitsModel Voltage Voltage Fan Heater Power MinimumV-Ph-60Hz Min Max FL

Pagina 69 -

COOLINGCAPACITIES(cont)SYSTEM38C*—IN-CEILINGCASSETTESYSTEM(38QR-C018WITH40QKE024)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM/B

Pagina 70

COOLINGCAPACITIES(cont)SYSTEM39C*—IN-CEILINGCASSETTESYSTEM(38QR-C024WITH40QKE036)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM/B

Pagina 71 - Rev "B"

COOLINGCAPACITIES(cont)SYSTEM40C*—IN-CEILINGCASSETTESYSTEM(38QR-C030WITH40QKE036)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR UNIT — CFM/B

Pagina 72 - Cooling and Heat Pump Models

COOLINGCAPACITIES(cont)SYSTEM41C*—IN-CEILINGCASSETTESYSTEM(38QR-C036SINGLE-PHASEUNITWITH40QKE048)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING IND

Pagina 73

COOLINGCAPACITIES(cont)SYSTEM42C*—IN-CEILINGCASSETTESYSTEM(38QR-C0363-PHASEUNITWITH40QKE048)TEMP (F)AIR ENTERINGOUTDOOR UNIT(Edb)AIR ENTERING INDOOR U

Pagina 74

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGSSYSTEM27H*—HIGHWALLSYSTEM(38BK009WITH40QNE009)TEMP (F)AIRENTERINGINDOOR UNITAIRENTERINGINDOOR UNIT(CFM)AIR TEM

Pagina 75

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM28H*—HIGHWALLSYSTEM(38BK012WITH40QNE012)TEMP (F)AIRENTERINGINDOOR UNITAIRENTERINGINDOOR UNIT(CFM)A

Pagina 76 - 01/11/02

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM29H*—HIGHWALLSYSTEM(38BK018WITH40QNE018)TEMP (F)AIRENTERINGINDOOR UNITAIRENTERINGINDOOR UNIT(CFM)A

Pagina 77 - Hydronic Cassette

INSTANTANEOUS ANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM30H*—HIGHWALLSYSTEM(38BK024WITH40QNE024)TEMP (F)AIRENTERINGINDOOR UNITAIRENTERINGINDOOR UNIT(CFM)

Pagina 78 - Cooling And Heat Pump Models

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM31H*—CEILING-SUSPENDEDSYSTEM(38QR-C018WITH40QAE024)TEMP (F)AIRENTERINGINDOOR UNITAIRENTERINGINDOOR

Pagina 79

Duct Free Systems - Electrical Data - 40 Series Console UnitsModel Voltage Voltage Fan Heater Power MinimumV-Ph-60Hz Min Max FLA kW F

Pagina 80

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM32H*—CEILING-SUSPENDEDSYSTEM(38QR-C024WITH40QAE024)TEMP (F)AIRENTERINGINDOOR UNITAIRENTERINGINDOOR

Pagina 81 - Cooling Models

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM33H*—CEILING-SUSPENDEDSYSTEM(38QR-C030WITH40QAE036)TEMP (F)AIRENTERINGINDOOR UNITAIRENTERINGINDOOR

Pagina 82

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM34H*—CEILING-SUSPENDEDSYSTEM(38QR-C036SINGLE-PHASEUNITWITH40QAE036)TEMP (F)AIRENTERINGINDOOR UNITA

Pagina 83

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM35H*—CEILING-SUSPENDEDSYSTEM(38QR-C0363-PHASEUNITWITH40QAE036)TEMP (F)AIRENTERINGINDOOR UNITAIRENT

Pagina 84 - Cooling Only Models

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM36H*—CEILING-SUSPENDEDSYSTEM(38QR-C048WITH40QAE048)TEMP (F)AIRENTERINGINDOOR UNITAIRENTERINGINDOOR

Pagina 85

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM37H*—CEILING-SUSPENDEDSYSTEM(38QR-C060WITH40QAE060)TEMP (F)AIRENTERINGINDOOR UNITAIRENTERINGINDOOR

Pagina 86 - Heat Pump Models

INSTANTANEOUS ANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM38H*—IN-CEILINGCASSETTESYSTEM(38QR-C018WITH40QKE024)TEMP (F)AIRENTERINGINDOOR AIRAIRENTERINGINDOO

Pagina 87

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM39H*—IN-CEILINGCASSETTESYSTEM(38QR-C024WITH40QKE036)TEMP (F)AIRENTERINGINDOOR UNITAIRENTERINGINDOO

Pagina 88

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM40H*—IN-CEILINGCASSETTESYSTEM(38QR-C030WITH40QKE036)TEMP (F)AIRENTERINGINDOOR UNITAIRENTERINGINDOO

Pagina 89 - Sound Data – Section 9

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM41H*—IN-CEILINGCASSETTESYSTEM(38QR-C036SINGLE-PHASEUNITWITH40QKE048)TEMP (F)AIRENTERINGINDOOR UNIT

Pagina 90 - 115v & 230v

Duct Free Systems - Electrical Data - 40 Series Cassette UnitsModel Voltage Voltage Fan Heater Power MinimumV-Ph-60Hz Min Max FLA kW

Pagina 91

INSTANTANEOUSANDINTEGRATEDHEATINGRATINGS(cont)SYSTEM42H*—IN-CEILINGCASSETTESYSTEM(38QR-C0363-PHASEUNITWITH40QKE048)TEMP (F)AIRENTERINGINDOOR UNITAIREN

Pagina 92 - Rev "A"

COOLINGCAPACITIESTABLENO.43*—38HDS024(or1Circuitof38HDS048System)CONDENSINGUNITWITHTWO40QKB024IN-CEILINGCASSETTEUNITSTEMP (F)AIR ENTERINGCONDENSER(Edb

Pagina 93

COOLINGCAPACITIES(cont)TABLENO.44*—38HDS024(or1Circuitof38HDS048System)CONDENSINGUNITWITHTWO40QAB024†CEILING-SUSPENDEDUNITSTEMP (F)AIR ENTERINGCONDENS

Pagina 94

COOLINGCAPACITIES(cont)TABLENO.45*—38HDS024(or1Circuitof38HDS048System)CONDENSINGUNITWITHTWO40QNB018HIGHWALLUNITSTEMP (F)AIR ENTERINGCONDENSER(Edb)AIR

Pagina 95

COOLINGCAPACITIES(cont)TABLENO.46*—38HDS024(or1Circuitof38HDS048System)CONDENSINGUNITWITHONE40QAB024†CEILING-SUSPENDEDUNITANDONE40QKB024IN-CEILINGCASS

Pagina 96

COOLINGCAPACITIES(cont)TABLENO.47*—38HDS024(or1Circuitof38HDS048System)CONDENSINGUNITWITHONE40QKB024IN-CEILINGCASSETTEUNITANDONE40QNB018HIGHWALLUNITTE

Pagina 97

COOLINGCAPACITIES(cont)TABLENO.48*—38HDS024(or1Circuitof38HDS048System)CONDENSINGUNITWITHONE40QAB024†CEILING-SUSPENDEDUNITANDONE40QNB018HIGHWALLUNITTE

Pagina 98

COOLINGCAPACITIES(cont)TABLENO.52*—38HDS024(or1Circuitof38HDS048System)CONDENSINGUNITWITHONE40QNB024HIGHWALLUNITTEMP (F)AIR ENTERINGCONDENSER(Edb)AIR

Pagina 99

COOLINGCAPACITIES(cont)TABLENO.53*—38HDS024(or1Circuitof38HDS048System)CONDENSINGUNITWITHONE40QAB024CEILING-SUSPENDEDUNITTEMP (F)AIR ENTERINGCONDENSER

Pagina 100 - 01/10/02

COOLINGCAPACITIES(cont)TABLENO.54*—38HDS024(or1Circuitof38HDS048System)CONDENSINGUNITWITHONE40QKB036IN-CEILINGCASSETTEUNITTEMP (F)AIR ENTERINGCONDENSE

Pagina 101

Duct Free Systems - Electrical Data - 40 Series Satellite Units Model Voltage Voltage Fan Heater Power MinimumV-Ph-60Hz Min Max F

Pagina 102 - Unit Specifications

COOLINGCAPACITIESTABLE NO. 55 - 42WKN004EnteringWaterTemp (F)WaterTempRise (F)Entering Air (F) — dry bulb72 80Entering Air (F) — wet bulb63 67 71 63 6

Pagina 103 - CFM - Cubic Feet Per Minute

COOLINGCAPACITIES(cont)TABLE NO. 57 - 42WKN010—2-TUBEEnteringWaterTemp (F)WaterTempRise (F)Entering Air (F) — dry bulb72 80Entering Air (F) — wet bulb

Pagina 104

COOLINGCAPACITIES(cont)TABLE NO. 59 - 42WKN016EnteringWaterTemp (F)WaterTempRise (F)Entering Air (F) — dry bulb72 80Entering Air (F) — wet bulb63 67 7

Pagina 105

COOLINGCAPACITIES(cont)TABLE NO. 61 - 42WKN020—4-TUBEEnteringWaterTemp (F)WaterTempRise (F)Entering Air (F) — dry bulb72 80Entering Air (F) — wet bulb

Pagina 106

Duct Free Systems - Piston/Charge CombinationsCooling Only High Wall Heat Pump High WallIndoor Outdoor AccuRater Charge Indoor Outdoor AccuRater AccuR

Pagina 107

Duct Free Systems - Piston/Charge CombinationsCooling Only High Wall Heat Pump High WallIndoor Outdoor AccuRater Charge Indoor Outdoor AccuRater AccuR

Pagina 108

Duct Free Systems - Piston/Charge CombinationsCooling Only High Wall Heat Pump High WallIndoor Outdoor AccuRater Charge Indoor Outdoor AccuRater AccuR

Pagina 109 - NOT AVAILABLE AT THIS TIME

Duct Free Systems - Piston/Charge CombinationsCooling Only High Wall Heat Pump High WallIndoor Outdoor AccuRater Charge Indoor Outdoor AccuRater AccuR

Pagina 110

Duct Free Systems - Piston/Charge CombinationsCooling Only High Wall Heat Pump High WallIndoor Outdoor AccuRater Charge Indoor Outdoor AccuRater AccuR

Pagina 111

Refrigerant and Long Line Applications– Section 15ApplicationApplicationAN009/012 & BK009/01238HDC38HDL38HDS38QRC & 38BK018/02438 C & S Se

Pagina 112

Maintenance/RepairApplicationProductInstallationInstallationApplicationProduct??HELPHELPDuct-Free Systems DigestDuct-Free Systems DigestMaintenance/Re

Pagina 113

Duct Free Systems - Electrical Data - CondensersModel Voltage Voltage Compressor Fan Power SupplyV-Ph-60Hz Min Max RLA LRA FLA MCA MOCP FLA38

Pagina 114

Refrigerant Lines – AN009/012 & BK009/012 1. The AN009/012 & BK009/012 are shipped with a full charge of R-22 refrigerant. Since all refrig

Pagina 115

Refrigerant Lines – 38HDC1. The 38HDC units are shipped with a full charge of R-22 refrigerant based on the smallest charge combination.2. All cha

Pagina 116 - Application

Long Line Applications – 38 HDC (continued)7. Changes in piston size. The metering device for long line applications must be adjusted to compensate f

Pagina 117 - Condenser Only Ratings

Refrigerant Lines - 38HDL1. The 38HDL units are shipped with a full charge of R-22 refrigerant based on the smallest charge combination.2. All charges

Pagina 118

Long Line Applications - 38HDL (continued)7. Changes in piston size. The metering device for long line applications must be adjusted to compensate f

Pagina 119 - Performance Data

Refrigerant Lines – 38HDS1. The 38HDS units are shipped with a full charge of R-22 refrigerant.2. All charges, line sizes and capacities are based o

Pagina 120

Refrigerant Lines – 38QRC & 38BK018/0241. The 38QR & BK018/024 units are shipped with a holding charge of R-22 refrigerant.2. All charges,

Pagina 121 - 11/30/01

Long Line Applications – 38QRC & 38BK018/024 (continued)7. Changes in piston size. The metering device for long line applications must be adjuste

Pagina 122

Refrigerant Lines – 38CG, CS, SB, & SC 1. The 38CG, CS, SB, & SC series condensers are shipped with a full charge of R-22 refrigerant. Sinc

Pagina 123 - COOLINGCAPACITIES

6. Lowered configuration: (Drop) Indoor unit below outdoor unit Diagram #4 a. The maximum elevation difference and the maximum equivalent length of

Pagina 124 - COOLINGCAPACITIES(cont)

Duct Free Systems - System ChargesCooling Only High Wall Heat Pump High Wall Heat Cool Under Ceiling COOLING WITH ELECTRIC HEATIndoor Outdoor System I

Pagina 125

Table #1 - Line Length's (Maximum)"B""C""A"ModelLiftDropTubeNote #1 Note #2Lgth38AN-009/012 30' 30' 50&ap

Pagina 126

Table #2 - Fitting Losses in Equivalent FeetTube Size O.D. (in)90 deg Short Radius90 deg Long Radius45 deg Short Radius5/8 1.6 1.0 0.83/4 1.8 1.2 0.97

Pagina 127

Table #3 - Effective Capacity LossNominalStdLongPercent of cooling capacity lossCapacityVaporVaporLineLine *50 ft75 ft100 ft125 ft150 ft175 ft200 ft18

Pagina 128

Table #4 - Calculation of Outdoor Piston Number Outdoor Unit Above Indoor UnitFeetPiston Change0-50 051-75 +476-100 +6101-125 +8

Pagina 129

Table #5 - Common Piston SizesAccuraterChatleffAccuraterChatleff- 32 65 65- 33 67 6735 35 - 68- 36 70 70- 37 - 7138 38 73 7339 - 7440 40 76 7641 78 78

Pagina 130

GROUND LEVELBASEMENTDiagram #1 * Not required for AN/BK009/012 –38 CG, SC, CS, SBSolenoid*"A"

Pagina 131

GROUND LEVELBASEMENTSolenoid*"A"Diagram #2 * Not required for AN/BK009/012 –38 CG, SC, CS, SB

Pagina 132

GROUND LEVELTRAP"B"Solenoid*Diagram #3 *Not required for AN/BK009/012 –38 CG, SC, CS, SB

Pagina 133

Solenoid*"C"Diagram #4 * Not required for AN/BK009/012 – 38 CG, SC, CS, SB

Pagina 134

SELECTION PROCEDURE (With Example) Rev “A” 09/19/01 I Determine the type of fan coil, which best suits the application (refer to S

Pagina 135

Duct Free Systems - System ChargesCooling Only High Wall Heat Pump High Wall Heat Cool Under Ceiling COOLING WITH ELECTRIC HEATIndoor Outdoor System I

Pagina 136

Drawings – Section 17ApplicationApplication40QN - 00940QN - 012 Cooling Only &

Pagina 137 - COOLING CAPACITIES

DIMENSIONAL DRAWING, BASE UNIT – 40QN009, 012 FAN COIL UNITSUNIT40QNWEIGHT A B CLb Kg in. mm in. mm in. mm009 18.7 8.5 33.46 850 11.02 280 6.29 160012

Pagina 138 - COOLING CAPACITIES (cont)

DIMENSIONAL DRAWING, BASE UNIT – 40QN018, 024 FAN COIL UNITSUNIT40QNWEIGHT018 39 Lb [17.5 Kg]024 43 Lb [19.5 Kg]NOTES:1. Dimensions in [ ] are in mill

Pagina 139

40QA BaseUnitDimensionsNOTES:1. Dimensions in [ ] are in millimeters.2. Direction of airflow.3. Standard unit clearances are as follows:•09on top and r

Pagina 140

UNIT40QK-OPERATING WEIGHTLb Kg024 61.6 28NOTES:1. indicates airflow.2. Dimensions in [ ] are in millimeters.3. Service clearance is 2 ft on control box

Pagina 141

UNIT40QK–OPERATING WEIGHTLb Kg036 105.8 48048* 118.0 53*OWO heat pump fan coil units only.NOTES:1. Indicates airflow.2. Dimensions in [ ] are in millim

Pagina 143

4Fig. 3 — 40HD036,048 Dimensional DrawingNOTES:1. Dimensions in [ ] are in millimeters.2. Center of gravity.3. Direction of airflow.4. Optional dir

Pagina 144

Drawings – Section 17ApplicationApplication38 AN 00938 AN - 012 38 HDC 018

Pagina 146

Duct Free Systems - System ChargesCooling Only High Wall Heat Pump High Wall Heat Cool Under Ceiling COOLING WITH ELECTRIC HEATIndoor Outdoor System I

Pagina 147

DIMENSIONALDRAWING,BASEUNIT—38HDSCONDENSINGUNITSUNITABCDEFGHFt-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm024 2-11⁄86

Pagina 148

DIMENSIONAL DRAWING, BASE UNIT – 38BK018, 024 HEAT PUMP UNITSUNITAB CDEFft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm018 2-11⁄8638.2 3-0

Pagina 151

DIMENSIONAL DRAWING, BASE UNIT – 38QR HEAT PUMP UNITSUNITABCDEFGHJKLMOPERATINGWEIGHTft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in.

Pagina 152

AccuRater It is extremely important that all refrigerant lines and the AccuRater metering device be insulated on heat pumps. On cooling only units

Pagina 153

Fig. 14 – AccuRater Metering Device at Service Valve (Bypass Type Components) Fig. 13 – AccuRater Metering Device in Liquid Line (Bypass type Compo

Pagina 154

Charge Verification – Section 19InstallationInstallation38HDC, HDL, QR, CG, CS38 HDS SB, SC (MULTISPLIT)

Pagina 155

REFRIGERANT CHARGING: WARNING: To prevent personal injury, wear safety glasses and gloves when handling refrigerant. Do not overcharge system compress

Pagina 157

Duct Free Systems - System ChargesCooling Only High Wall Heat Pump High Wall Heat Cool Under Ceiling COOLING WITH ELECTRIC HEATIndoor Outdoor System I

Pagina 159

REFRIGERANT CHARGING (Multi Split) WARNING: To prevent personal injury, wear safety glasses and gloves when handling refrigerant. Do not overcharge s

Pagina 160

Table 8 – Required Liquid Line Temperatures Table 7 – Required Unit Subcooling Figure 14 – Vapor Supply Line Measurement Locations (048 Unit Shown)

Pagina 161

Controls – Section 20InstallationInstallationHigh WallUnder Ceiling, Cassette, & Satellite38HDSConsole

Pagina 162

Controls — systems using high wall fan coils 40QNB/QNE control system The 40QN unit is equipped with a microprocessor control, which operates the sy

Pagina 163

• Maximum Dehumidification Mode — When the dehumidification mode is selected, the indoor fan will operate continuously at the selected speed if the s

Pagina 164

• Awake Mode — The awake timer will turn the unit on when the timer reaches zero minutes. The unit will start in the same mode and at the same selecte

Pagina 165

*Minimum unit run time starts when outdoor coil temperature drops below 34 F, then accumulates runtime regardless of coil temperature.ElectronicContro

Pagina 167

Controls — systems using Under Ceiling, Cassette or Satellite fan coils Automatic air sweep All Under Ceiling units are equipped with an automatic air

Pagina 168

Duct Free Systems - System ChargesCooling Only High Wall Heat Pump High Wall Heat Cool Under Ceiling COOLING WITH ELECTRIC HEATIndoor Outdoor System I

Pagina 169

DFB switches the unit back to normal heating operation. If the DFT remains closed the DFB switches the unit back to heating operation after 10 minutes

Pagina 170

Controls - 38HDS Unit operation NOTE: AUTO fan mode is used as the unit operation example for ALL fan coil units in this section. Contact your local C

Pagina 171

the 38HDS microprocessor if the other refrigerant circuit is still operating. The outdoor fan only stops when both compressors are off. Refer to 38HD

Pagina 172

ThermostatInstallationInstallationOperationPhotographs and illustrations

Pagina 173

3 AIR CONDITIONER OPERATION MODE Your Carrier Duct Free air conditioner operates in four modes:The air conditioner cools, dries, and filters the roo

Pagina 174

4 • When transmitting a command from the remote controller,point the transmitter toward the receiver on the right side of theair conditioner.• The a

Pagina 175

5 INSERTING BATTERIES IN THE REMOTE CONTROLLER Before using the remote controller you must insert two 1.5VAAA Alkaline batteries, as follows:• Slide

Pagina 176

6 • Press the On/Off button 3 to transmit your selections to theair conditioner1. If you choose to place the airflow deflector in a fixed posi-tion

Pagina 177

7 • Scroll through the Timer periods as explained in the previoussection • Choose the SLEEP Timer period• Enter the desired Start/Stop times (SLEEP

Pagina 178

8 When the air conditioner is OFF: • Press DELAY button. The clock advances one hour, while theword START and the number 3 flash.• Each additional p

Pagina 179

Duct Free Systems - System ChargesCooling Only High Wall Heat Pump High Wall Heat Cool Under Ceiling COOLING WITH ELECTRIC HEATIndoor Outdoor System I

Pagina 180

9 MORE ON NEXT PAGE airborne particles. More frequent cleaning may be neces-sary depending on indoor

Pagina 181

53DFST2-NP 53DFS250-SL 53DFS250-FS Fig #3

Pagina 182

Installation Diagrams – Section 22InstallationInstallation40 QN 009 & 01240 QN 018 & 024

Pagina 183

TYPICAL INSTALLATION — HIGH-WALL SYSTEMS, 9,000 AND 12,000 BTUH(Cooling-Only System Shown)LEGENDNEC — National Electrical Code*Standard.†Field supplie

Pagina 184

TYPICAL INSTALLATION — HIGH-WALL SYSTEMS, 18,000 AND 24,000 BTUH(Cooling Only System Shown)LEGENDNEC — National Electrical CodePipingLine Voltage24 VT

Pagina 185

Installation Diagrams – Section 22InstallationInstallation40 QA40 C

Pagina 186

TYPICAL INSTALLATION — CEILING-SUSPENDED SYSTEMSLEGENDf — PhaseNEC — National Electrical CodePipingLine Voltage24 VThermistor*Standard.†Accessory item

Pagina 187

FIELD SUPPLIEDFUSEDDISCONNECTAND WIRINGPER NECWIRELESSCONTROLLERFIELD SUPPLIED WEATHERPROOFFUSED DISCONNECT AND WIRINGPER NECINSULATEDLIQUID LINEOUTD

Pagina 188

Installation Diagrams – Section 22InstallationInstallation40 QK40 HD

Pagina 189

TYPICAL INSTALLATION — IN-CEILING CASSETTE SYSTEMSLEGENDf — PhaseNEC — National Electrical CodePipingLine Voltage24 V*Standard.†Accessory item.**Field

Pagina 190

Duct Free SystemsHigh Wall Features and AccessoriesOutdoor Section/Indoor SectionFeatureAN/QNBBK/QNEBK/QNHBK/QNHHDC/QNBHDL/QNBHDS/QNBAll009

Pagina 191

FIELD SUPPLIEDTYPE L REFRIGERANTTUBINGFIELD SUPPLIEDFILTER DRIERFIELD SUPPLIED24 V CONTROLWIRINGFIELD SUPPLIEDCONDENSATEDRAIN LINETO OPEN DRAINFIELD

Pagina 192

Service – Section 23InstallationInstallation40 QN – High Wall40 QA – Under Ceiling40 CG and CS – Console40 HD – Satellite40 QK – Cassette

Pagina 193

SERVICE – High Wall Systems WARNING: When servicing unit, turn off all electric power to unit to avoid shock hazard or injury from rotating parts. C

Pagina 194 - 38HDC048-3,5,6

Compressor Short Cycling Protection There is a time delay of 3 minutes between compressor turning off and turning back on. Indoor Coil Freeze Protec

Pagina 196

SERVICE Under Ceiling, Cassette, Console, & Satellite Fan Coils WARNING: When servicing unit, turn off all electric power to unit to avoid shock

Pagina 197

Service – Section 23InstallationInstallation38 HDC, 38 QR, & BK 018, 02438 HDS38 HDL38 CG, CS, SC, & SB

Pagina 198

SERVICE – 38HDC, 38QR, & 38BK018,024 WARNING: Before performing recommended maintenance, be sure unit main power switch is turned off. Failure t

Pagina 199 - – Section 15

NOTE: If pressure switch needs to be replaced, there is a Schrader valve located under the switch so that system will not need to be evacuated. CRANK

Pagina 200

Discharge Temperature Switch (DTS) Heat Pump Only Switch used only on sizes 030 and 036 with scroll compressors, senses high discharge temperature lev

Pagina 201

Duct Free SystemsUnder Ceiling Features and AccessoriesFeature Under Ceiling Outdoor/IndoorHDC/QAB HDL/QAB HDS/QAB QR/QAEAccumulator Standa

Pagina 203

SERVICE – 38HDL WARNING: Before performing recommended maintenance, be sure unit main power switch is turned off. Failure to do so may result in elec

Pagina 204

Fig. 11 – Condenser Fan Mounting Positions

Pagina 205

SERVICE – Multi Split WARNING: Before performing recommended maintenance, be sure unit main power switch is turned off, and be sure all disconnects f

Pagina 206

LOW-PRESSURE SWITCH This switch, mounted on the vapor return line, has fixed non-adjustable settings. To check pressure switch, attach pressure gage t

Pagina 207

Figure 13 – Condenser-Fan Mounting Positions

Pagina 208

SERVICE – 38CG, CS, SB, & SC WARNING: Before performing recommended maintenance, be sure unit main power switch is turned off. Failure to do so m

Pagina 209

Start-Up Instructions – Section 24InstallationInstallation40 QNCheck List

Pagina 210

START-UP – High Wall Systems Complete the following checks and the Start-Up checklist before system start-up. Refer to outdoor unit installation, sta

Pagina 211

Start-Up Instructions – Section 24InstallationInstallation40 C – Console40 QA – Under CeilingCheck List

Pagina 212

Duct Free SystemsConsole Features and AccessoriesFeature Console Outdoor/Indoor38CG/40CG 38CS/40CS 38SC/40CG 38SB/40CSAccumulator N/A N/A N

Pagina 213

START-UP – Under Ceiling Systems WARNING: Never operate unit without a filter or with grille removed; damage to the unit or personal injury may resul

Pagina 214

START-UP – Console Systems WARNING: Never operate unit without a filter or with grille removed; damage to the unit or personal injury may result. Mak

Pagina 215 - "A"

Start-Up Instructions – Section 24InstallationInstallation40 QKCheck List

Pagina 216 - Diagram #2

START-UP - Cassette Units Make the following checks and complete the Start-Up Checklist before system start-up. Refer to outdoor unit Installation, S

Pagina 217 - "B"

Start-Up Instructions – Section 24InstallationInstallation40 HDCheck List

Pagina 218 - "C"

START-UP - Satellite Units Make the following checks and complete the Start-Up Checklist before system start-up. Refer to outdoor unit Installation,

Pagina 219 - Builder Module

Start-Up Instructions – Section 24InstallationInstallation38 HDC38 HDL38 HDS38 QR38 AN/BK 009 & 012Check List

Pagina 220 - Drawings – Section 17

START-UP - Multi-Split LEAK TEST Field piping and all tubing connections must be leak tested by the pressure method. Use R-22 at approximately 25 psi

Pagina 221

START-UP – 38HDC, 38HDL, & 38QR NOTE: All outdoor units with a reciprocating compressor have a crankcase heater. Heater should be energized for a

Pagina 222

START-UP CHECKLIST Outdoor Unit: Model Number ________________ Serial Number ____________________ Indoor Unit: Model Number __________________

Pagina 223 - 40QA BaseUnitDimensions

ARI* Capacities High Wall ApplicationsIndoor Outdoor Std. Net Cooling Total SEER EER Heating Heating Heating Heating HeatingSection Section CFM BTUH

Pagina 224

Duct Free SystemsCassette Features and AccessoriesFeature Outdoor Section/Indoor SectionHDC/QKBHDL/QKBHDS/QKBQR/QKEAccumulator

Pagina 225

CHECK MOUNTING OF SUBBASE TO WALL, IS IT TIGHT (DO NOT APPLY EXCESSIVE FORCE TO MOUNTING SCREW)? (Y/N) _____ Units with Wireless Remote Controller CH

Pagina 226

Wire Diagrams (Under Development)InstallationInstallation40QNB009 to 38AN00940QNB012 to 38AN01240QNB018 to 38HDC018

Pagina 227

Wire Diagrams (Under Development)InstallationInstallation40QAB024-3 to 38HDC018-340QAB024-3 to 38HDL018-340QAB024-3 to 38HDC024-340QAB024-3 to 38HDL02

Pagina 228

Wire Diagrams (Under Development)InstallationInstallation40QKB024-3 to 38HDC018-340QKB024-3 to 38HDL018-340QKB036-3 to 38HDC024-340QKB036-3 to 38HDL02

Pagina 229

Cleaning & Maintenance – Section 26Maintenance/RepairMaintenance/Repair40QN

Pagina 230

40 QN CLEANINGANDMAINTENANCETo avoid the possibility of electric shock, before per-forming any cleaning and maintenance operations al-ways turn off po

Pagina 231

To Clean Indoor Unit Front Panel — If the frontpanel of the unit becomes dirty or smudged, wipe the out-side of the front panel with a soft dry cloth.

Pagina 232

Cleaning & Maintenace – Section 26Maintenance/RepairMaintenance/Repair40 QA40 CG, CS

Pagina 233

40 QA CLEANINGANDMAINTENANCETo avoid the possibility of electric shock, before per-forming any cleaning and maintenance operations, al-ways turn off p

Pagina 234

Table 8 – Cleaning and Maintenance ScheduleTASK MONTHLY QUARTERLY YEARLYINDOOR UNITClean Air Filters XClean Drain Pipe XClean Condensate Drain Pan XCl

Pagina 235 - Cleaning and/or Replacing

Duct Free SystemsSatellite Features and AccessoriesFeature Outdoor Section/Indoor SectionHDC/40HD HDL/40HD QR/40HDAccumulator Standard

Pagina 236 - OUTDOOR UNIT

40 CG, CS CARE AND MAINTENANCE Step 1 – Maintenance (Outdoor Unit) WARNING Before performing recommended maintenance, be sure unit main power switch

Pagina 237 - Installation

Cleaning & Maintenance – Section 26Maintenance/RepairMaintenance/Repair40 QK

Pagina 238

40 QK SERVICE AND MAINTENANCERemove unit grille, filter, and condensate pan for clean-ing, lubricating, or replacing parts.To avoid personal injury or

Pagina 239

Cleaning & Maintenance – Section 26Maintenance/RepairMaintenance/Repair40 HD

Pagina 240

40 HD CLEANING AND MAINTENANCE To avoid the possibility of electrical shock, before performing any cleaning and maintenance operations, always turn o

Pagina 241 - Subcooling Charging Method

Cleaning & Maintenance – Section 26Maintenance/RepairMaintenance/Repair38 HDC38 HDL38 HDS38 QR38 AN38 BK38 CG, CS, SB, SC

Pagina 242 - Locations (048 Unit Shown)

38 HDC, 38 HDL, 38 QR MAINTENANCE WARNING Before performing recommended maintenance, be sure unit main power switch is turned off. Failure to do so

Pagina 243 - Controls – Section 20

38 HDS MAINTENANCE WARNING Before performing recommended maintenance, be sure unit main power switch is turned off. Failure to do so may result in e

Pagina 244

38 AN, 38 BK CLEANINGANDMAINTENANCETo avoid the possibility of electric shock, before per-forming any cleaning and maintenance operations al-ways turn

Pagina 245

To Clean Indoor Unit Front Panel — If the frontpanel of the unit becomes dirty or smudged, wipe the out-side of the front panel with a soft dry cloth.

Pagina 246

Accessories – Field Installed Low Ambient Kit: The Low Ambient Kit is a solid state head pressure controller designed to control condenser fan cyclin

Pagina 247

38 CG, CS, SB, SC CARE AND MAINTENANCE Step 1 – Maintenance (Outdoor Unit) WARNING Before performing recommended maintenance, be sure unit main powe

Pagina 248

Troubleshooting & Fault Codes – Section 27Maintenance/RepairMaintenance/Repair40 QN – Troubleshooting40 QN – Fault Codes

Pagina 249 - Operating sequence

HWError Code.doc MORE ON NEXT PAGE 2/09/01 Troubleshooting

Pagina 250

HWError Code.doc 02/09/01 • Check CN1 plug for voltage If voltage is recorded at the CN1 plug and LED does not flash, replace board. Insufficient

Pagina 251 - Controls - 38HDS

HWError Code.doc MORE ON NEXT PAGE 02/09/01 High Wall Dia

Pagina 252

HWError Code.doc 02/09/01 7 Outdoor Air thermistor malfunction If the following occurs with thermistor: Short condition: greater or = 194 deg F

Pagina 253 - Thermostat

Troubleshooting & Fault Codes – Section 27Maintenance/RepairMaintenance/Repair40 QA – TroubleshootingThermostat – see Controls40 CG, CS Troublesho

Pagina 254 - WIRELESS REMOTE CONTROLLER

TROUBLESHOOTINGIf the under-ceiling fan coil unit fails to start or operateproperly, sometimes the problem is minor and can be handledwithout a servic

Pagina 255 - Up/Down Button

FAULT CODES Table 6 – Indicator Lamps Troubleshooting LAMP STATUS INDICATION CORRECTIVE ACTION POWER flashes 10 seconds after A/C start-up (with or

Pagina 256 - IMPORTANT

TROUBLESHOOTING Table 7 – General Troubleshooting Chart (Page 1 of 2; Go to Page 2) SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION a. Power supply to uni

Pagina 257

Filter Rack Package – A fully assembled 2” Filter Rack and 1” T.A.W. filter with side access Multi-zone Adapter – Duct collars, internal insulation,

Pagina 258

Table 7 – General Troubleshooting Chart (Page 2 of 2; Return to Page 1) SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Water accumulates and overflows fro

Pagina 259 - ENERGY-SAVING TIPS

Troubleshooting & Fault Codes – Section 27Maintenance/RepairMaintenance/Repair40 QK – TroubleshootingThermostat – see Controls

Pagina 260 - Cover open

Trouble Shooting – Cassette If any of the original wire furnished must be replaced, it must be replaced with type 90 deg C or its equivalent. Wire i

Pagina 261

Troubleshooting & Fault Codes – Section 27Maintenance/RepairMaintenance/Repair40 HD – TroubleshootingThermostat – see Controls

Pagina 262

Trouble Shooting – Satellite If any of the original wire furnished must be replaced, it must be replaced with type 90 deg C or its equivalent. Wire

Pagina 263 - (Cooling-Only System Shown)

Troubleshooting & Fault Codes – Section 27Maintenance/RepairMaintenance/Repair38 HDC – Troubleshooting38 HDL – Troubleshooting38 HDS – Troubleshoo

Pagina 264 - (Cooling Only System Shown)

TROUBLESHOOTING CHART — COOLING CYCLENC — Normally Closed*Heat pump units only.

Pagina 265

LEGENDHPS — High-Pressure SwitchLLSV — Liquid (Vapor Supply) Line Solenoid ValveLPS — Low-Pressure SwitchTXV — Thermostatic Expansion ValveTROUBLESHOO

Pagina 266

TROUBLESHOOTING CHART — HEATING CYCLE(Heat Pump Units Only)LEGENDCAP — CapillaryNC — Normally ClosedODT — Outdoor ThermostatTEMP — Temperature

Pagina 268

Charcoal Filter Kit: The charcoal (carbon) filter kit is available for High Wall fan coils. This accessory improves indoor air quality by removing

Pagina 269

TROUBLESHOOTING Table 6 – Indicator Lamps Troubleshooting LAMP STATUS INDICATION CORRECTIVE ACTION POWER flashes 10 seconds after A/C start-up (wi

Pagina 270

TROUBLESHOOTING Table 7 – General Troubleshooting Chart (Page 1 of 2; Go to Page 2) SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION a. Power supply to uni

Pagina 271 - Service – Section 23

Table 7 – General Troubleshooting Chart (Page 2 of 2; Return to Page 1) SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Water accumulates and overflows fro

Pagina 272 - SERVICE – High Wall Systems

Condensate pumps provide lift capability per the tablebelow:High Wall 009 1ft to 10ft AccessoryHigh Wall 012-024 3ft to 25 ft AccessoryUnder ceiling 2

Pagina 273

Dimensional DrawingOPENSIZEBACKOPENINGS2345676A(in.) 9.1 13.4 17.7 22.1 26.4 30.7(mm) 230 340 450 560 670 780B(in.) 11.2 15.5 19.85 24.2 28.

Pagina 274

Guide Specifications – Section 6ProductProductHigh-Wall Heat Pump UnitsHigh-Wall Cooling Only UnitsCeiling-Suspended Cooling Only UnitsCeiling Suspend

Pagina 275 - SERVICE

Guide Specifications High-Wall Heat Pump Units HVAC Guide Specifications Size range: ¾ to 2 Tons Cooling Capacity Carrier Model Number: 40QNE/H &a

Pagina 276

D. Coil: Coil shall be copper tube with aluminum fins and galvanized steel tube sheets. Fins shall be bonded to the tubes by mechanical expansion.

Pagina 277

ARI* CapacitiesUnder Ceiling ApplicationsIndoor Outdoor Std. Net Cooling Total SEER EER Heating Heating Heating Heating HeatingSection Section CFM BTU

Pagina 278 - REVERSING VALVE

G. Filters: Unit shall have filter track with factory-supplied cleanable filters. H. Electrical Requirements: Unit shall operate on 115 v (009), 208

Pagina 279 - Thermistors

Guide Specifications High-Wall Cooling Only Units HVAC Guide Specifications Size range: ¾ to 2 Tons Cooling Capacity Carrier Model Number:

Pagina 280

D. Coil: Coil shall be copper tube with aluminum fins and galvanized steel tube sheets. Fins shall be bonded to the tubes by mechanical expansion.

Pagina 281 - SERVICE – 38HDL

H. Electrical Requirements: Unit shall operate on 115-v (009 & 012), or 208/230 v (012-024), 60 Hz power supply as specified on the equipment sche

Pagina 282

Guide Specifications Ceiling Suspended Cooling Only Units HVAC Guide Specifications Size range: 1 ½ to 5 Tons Cooling Capacity Carrier Model Numb

Pagina 283 - SERVICE – Multi Split

E. Motors: Motors shall be permanently lubricated ball bearing with inherent overload protection. Fan motors shall be 3-speed. F. Controls: Controls

Pagina 284 - LOW-PRESSURE SWITCH

J. Special Features (Field Installed): Certain features are not applicable when the features designated by * are specified. For assistance in amendi

Pagina 285

Guide Specifications Ceiling Suspended Heat Pump Units HVAC Guide Specifications Size range: 1 ½ to 5 Tons Cooling Capacity Carrier Model Number

Pagina 286

Note: The units use the AccuRater piston refrigerant metering device in the indoor unit (for cooling) and at the outdoor unit liquid line service val

Pagina 287

I. Operating Characteristics: ARI Capacities Sound Rating (dBa) Indoor Unit Outdoor Unit C/O Btuh H/P Btuh ARI CFM Air* Entering Condenser Air* Ent

Pagina 288

ARI* CapacitiesConsole ApplicationsIndoor Outdoor Std. Net Cooling Total SEER EER Heating Heating Heating Heating HeatingSection Section CFM BTUH kW H

Pagina 289

1 Guide Specifications Console/Ceiling Suspended Cooling Only System Heat Pump System (With Supplemental Electric Heat) Multi-Zone System (Coolin

Pagina 290

2 1.04 WARRANTY One-year parts, 5-year compressor limited warranty Part 2 – Product 2.01 EQUIPMENT A. Unit Cabinet: Outdoor cabinet shall be z

Pagina 291

3 MORE ON NEXT PAGE 5. Filter needs cleaning status indication. 6. Automatic airsweep control to provide on or off activ

Pagina 292

4 I. Special Capabilities (Field Installed): 1. Fresh Air Intake: A field installed grille to provide for outdoor ventilation air when indoor unit

Pagina 293 - START-UP - Cassette Units

Guide Specifications In-Ceiling Cassette Cooling Only Units HVAC Guide Specifications Size range: 1 ½ to 3 Tons Cooling Capacity Carrier Model N

Pagina 294

D. Coil: Coil shall be copper tube with aluminum fins and galvanized steel tube sheets. Fins shall be bonded to the tubes by mechanical expansion. A

Pagina 295 - START-UP - Satellite Units

K. Special Features (Field Installed): 1. Fresh Air Intake Kit: Kit shall include filter and duct connections to provide for outdoor ventilation ai

Pagina 296

Guide Specifications In-Ceiling Cassette Heat Pump Units HVAC Guide Specifications Size range: 1 ½ to 3 Tons Cooling Capacity Carrier Model Numb

Pagina 297 - START-UP - Multi-Split

D. Coil: Coil shall be copper tube with aluminum fins and galvanized steel tube sheets. Fins shall be bonded to the tubes by mechanical expansion.

Pagina 298

K. Special Features (Field Installed): 1. Fresh Air Intake Kit: Kit shall include filter and duct connections to provide for outdoor ventilation

Pagina 299

ARI* Capacities In Ceiling Cassette ApplicationsIndoor Outdoor Std. Net Cooling Total SEER EER Heating Heating Heating Heating HeatingSection Section

Pagina 300 - Power Supply

Guide Specifications Outdoor Heat Pump Only Units Commercial Condensing Units HVAC Guide Specifications Size range: ¾ to 5 Tons Cooling Capacity C

Pagina 301

Part 2 – Products 2.01 EQUIPMENT A. General: Factory assembled, single piece, air-cooled outdoor unit. Contained within the unit enclosure shall be

Pagina 302

E. Outdoor Coil: Coil shall be constructed of aluminum fins mechanically bonded to internally enhanced, seamless copper tubes which are cleaned, dehyd

Pagina 303

2. Liquid Solenoid Valve: This electronically operated shutoff valve shall close and open in response to compressor operation. The valve should be

Pagina 304 - Maintenance/Repair

Guide Specifications Outdoor Cooling Only Units Commercial (AN/HDC) Light Commercial (HDL) Condensing Units HVAC Guide Specifications Size range:

Pagina 305

Part 2 – Products 2.01 EQUIPMENT A. General: Factory assembled, single piece, air-cooled outdoor unit. Contained within the unit enclosure shall be

Pagina 306 - PRESS TA SET TIME PRESS TA

F. Refrigeration Components: Refrigerant circuit components shall include brass external liquid line service valve with service gage port connections,

Pagina 307

2. Liquid Solenoid Valve: This electronically operated shutoff valve shall close and open in response to compressor operation. The valve should be

Pagina 308 - (Fig. 23)

Guide Specifications Satellite Systems Cooling Only Units HVAC Guide Specifications Size range: 2, 3, & 4 Tons Cooling Capacity Carrier Model

Pagina 309

E. Motors: Motors shall be permanently lubricated ball bearing with inherent overload protection. Fan motors shall be 3-speed. F. Internal Condensa

Pagina 310

ARI* Capacities Hydronic Cassette ApplicationsUnit Pipe Std. Net Cooling Sensible Heating Gallons PressureSize Version CFM (Btuh) Cooling (Btuh) Per

Pagina 311

K. Special Features (Field Installed): Electronic Programmable Thermostat- Thermostat shall be commercial grade and shall provide 7-day, 4-event sc

Pagina 312 - INSTALLATION OPTIONS

38 Series Model Number Nomenclature38 xx xxx xVoltageAir Cooled Condenser 1=115-1-603=208/230-1-605=208/230-3-60Unit Type 6=460-3-60AN - Cooling Only

Pagina 313

Physical Data : High Wall – Section 8ProductProductCooling and Heat Pump Models

Pagina 314

Duct Free Systems - Physical Data - 40 Series High Wall UnitsCooling and Heat Pump ModelsQNB009*** QNB012-1*** QNB012-3*** QNB018** QNB024** QNE009* Q

Pagina 315

Physical Data : Under Ceiling/Console -- Section 8ProductProductCooling Only and Heat Pump Models – Under CeilingCooling Only and Heat Pump Models – C

Pagina 316 - WARNING

Duct Free Systems - Physical Data - 40 Series Under Ceiling UnitsQAB018^ QAB024 QAB036 QAB048 QAB060 QAE018^ QAE024 QAE036 QAE048 QAE06

Pagina 317

Duct Free Systems - Physical Data - 40 Series Console Units40CG018 40CG024 40CG030 40CS018 40CS024 40CS030Nominal Capacity (

Pagina 318

Physical Data : Cassette – Section 8ProductProductCooling and Heat Pump ModelsHydronic Cassette

Pagina 319

Duct Free Systems - Physical Data - 40 Series Cassette UnitsCooling And Heat Pump ModelsQKB024 QKB036* QKB036 QKE024 QKE036 QKE048Nominal C

Pagina 320

Duct Free Systems - Physical Data - Hydronic CassetteUnit 42WKN 004 008 010 016 020Pipe Versio

Pagina 321

ARI* Capacities Multi Split Applications Page 1 of 2; Go to Page 2Nom

Pagina 322 - Troubleshooting

Physical Data : Satellite – Section 8ProductProductCooling Only and Heat Pump Models

Pagina 323

Duct Free Systems - Physical Data - 40 Series Satellite UnitsCooling Models40HD024 40HD036 40HD048Nominal Capacity (Tons)2 3.0 4.0Operating Weight88

Pagina 324 - High Wall Diagnostic Codes

Physical Data : Condenser – Section 8ProductProduct38 Series AN & BK Condensers38 Series HDC Condensers38 Series HDL Condensers38 Series QRC Conde

Pagina 325 - Indoor Fan failure

Duct Free Systems - Physical Data - 38 Series AN & BK CondensersCooling Only and Heat Pump ModelsAN009 * AN012-1 * AN012-3 *

Pagina 326

Duct Free Systems - Physical Data - 38 Series HDC CondensersCooling Only ModelsHDC018 HDC024 HDC030 HDC036-3 HDC036-5/6 HDC048-3

Pagina 327 - TROUBLESHOOTING

Duct Free Systems - Physical Data - 38 Series HDL CondensersCooling Only ModelsHDL018 HDL024 HDL030 HDL036301 HDL036311 HDL048 HD

Pagina 328 - MORE ON NEXT PAGE

Duct Free Systems - Physical Data - 38 Series QRC CondensersHeat Pump ModelsQR018C QR024C QR030C QR036C-3 QR036C-5/6 QR048C-3 QR0

Pagina 329

Duct Free Systems - Physical Data - 38 Series HDS CondensersCooling Only ModelsHDS024 HDS048Nominal Capacity (Tons)2.0 4.0Operati

Pagina 330

Duct Free Systems - Physical Data - 38CG, CS, SB, & SC Series CondensersCooling Only & Heat Pump Models38CG018 38CG024 38CG030 38CS018 38CS024

Pagina 331

Sound Data – Section 9ProductProductHigh WallUnder CeilingConsoleCassetteSatelliteCondenser

Pagina 332

ARI* Capacities Multi Split Applications Page 2 of 2; Go to Page 1Nom

Pagina 333

Sound Data "High Wall" Fan Coils (A Weighed)Model Sound Sound Fan Sound Power Data Octave Band (dBa)Pressure (dBa) Power (dBa) Speed 125 2

Pagina 334

Sound Data "Under Ceiling" Fan Coils (A Weighted)Model Sound Sound Fan Sound Power Data Octave Band (dBa)Pressure (dBa) Power (dBa) Speed

Pagina 335

Sound Data "Console" Fan Coils (A Weighted)Model Sound Sound Fan Sound Power Data Octave Band (dBa)Pressure (dBa) Power (dBa) Speed 125 2

Pagina 336 - *Heat pump units only

Sound Data "Cassette" Fan Coils (A Weighted)Model Sound Sound Fan Sound Power Data Octave Band (dBa)Pressure (dBa) Power (dBa) Speed 125

Pagina 337 - LPS — Low-Pressure Switch

Sound Data "Hydronic Cassette" Fan Coils (A Weighted)Model Sound Sound Fan Sound Power Data Octave Band (dBa)Pressure (dBa) Power (dBa) Sp

Pagina 338 - TEMP — Temperature

Sound Data "Satellite" Fan Coils (A Weighted)Model Sound Sound Fan Sound Power Data Octave Band (dBa)Pressure (dBa) Power (dBa) Speed 125

Pagina 339

Sound Data "Condensers" (A Weighted)Model Sound Sound Sound Fan Sound Power Data Octave Band (dBa)Power #1(dBa) Power #2(dBa) Pessure (dBa

Pagina 340

System Cross MatchCooling Only High Wall Heat Pump High WallNominal Indoor Indoor Outdoor Outdoor Nominal Indoor Indoor Outdoor OutdoorCapacity Unit U

Pagina 341

System Cross MatchCooling Only High Wall Heat Pump High WallNominal Indoor Indoor Outdoor Outdoor Nominal Indoor Indoor Outdoor OutdoorCapacity Unit U

Pagina 342

System Cross MatchCooling Only High Wall Heat Pump High WallNominal Indoor Indoor Outdoor Outdoor Nominal Indoor Indoor Outdoor OutdoorCapacity Unit U