SYSTXCCUID01-- B
Infinityt Control
Installation Instructions
HOLD
COOL
HEAT
OFF
A03149
Fig. 1 -- Infinityt Control
NOTE: Read the entire instruction manual before starting the
installation.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS 1.........................
INTRODUCTION 1...................................
INSTALLATION AND START--UP OVERVIEW 1..........
INSTALLATION 2....................................
INSTALLING INFINITY CONTROL 4....................
INITIAL POWER--UP 5................................
QUICK START 7.....................................
INSTALL / SERVICE MENUS 7.........................
EQUIPMENT SUMMARY MENU 8......................
INSTALL MENU 8....................................
SETUP MENU 8......................................
CHECKOUT MENUS 12...............................
SERVICE MENUS 12..................................
OPERATIONAL INFORMATION 14.....................
TROUBLESHOOTING 15..............................
SYSTEM MALFUNCTION SCREEN 16..................
SAFETY CONSIDERATIONS
Read and follow manufacturer instructions carefully. Follow all
local electrical codes during installation. All wiring must conform
to local and national electrical codes. Improper wiring or
installation may damage the Infinity System.
Recognize safety information. This is the safety--alert symbol
.
When you see this symbol on the equipment and in the instruction
manual, be alert to the potential for personal injury. Understand the
signal words DANGER, WARNING, and CAUTION.
These words are used with the safety--alert symbol. DANGER
identifies the most serious hazards, which will result in severe
personal injury or death. WARNING signifies a hazard, which
could result in personal injury or death. CAUTION is used to
identify unsafe practices, which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
INTRODUCTION
The Infinity System consists of several intelligent communicating
components which includes the Infinity Control (or User
Interface), variable speed furnace or FE fan coil, 2--stage AC or HP
and Infinity Packaged Products, which continually communicate
with each other via a four--wire connection called the ABCD bus.
Commands, operating conditions, and other data are passed
continually between co mponents over the ABCD bus. The result is
a new level of comfort, versatility, and simplicity.
All Infinity furnaces or fan coils are variable--speed and multi stage
for maximum flexibility, efficiency , and comfort. They support
controlled ventilation, humidification, dehumidification, and air
quality control. Either an Infinity (communicating), or a standard
24VAC controlled outdoor unit may be used.
When using conventional outdoor units, the Infinity furnace or fan
coil provides the 24 volt signals needed to control them. Also, the
Infinity Network Interface Module (P/N SYSTXCCNIM01) allows
connection of a Carrier HRV or ERV without the need for a
separate wall control.
All system components are controlled through the wall mounted
Infinity Control, which replaces the conventional thermostat and
provides the homeowner with a single wall control for all features
of the system.
INSTALLATION AND START--UP
OVER VIEW
This instruction covers installation of the Infinity Control only.
Physical installation instructions for the indoor and outdoor
equipment, and accessories are provided with each unit.
Setup, commissioning, operation, and troubleshooting of the
Infinity System are covered only in this installation instruction. It is
the guide to connecting the system components and
commissioning the system once all physical components are
installed. Special screen prompts and start--up capabilities are
provided in the Infinity System to simplify and automate the initial
commissioning of the system.
S Install Infinity Control according to this instruction.
S Install indoor unit, outdoor unit, and accessories according to
their instructions.
S Wire complete system according to this instruction.
S Setup, commission, and operate system according to this
instruction to assure a smooth and trouble free start-- up.
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - Installation Instructions

SYSTXCCUID01-- BInfinityt ControlInstallation InstructionsHOLDCOOLHEATOFFA03149Fig. 1 -- Infinityt ControlNOTE: Read the entire instruction manual bef

Pagina 2 - INSTALLATION

10Setup -- Fan CoilHP/AC Airflow:S COMFORT (default) Cooling airflow is varied depending onhumidity and temperature demand settings. This selectionena

Pagina 3

11Setup -- Hybrid Heat HYBRID HEAT SETUPFURNACELOCKOUT:> 30 FHEAT PUMPLOCKOUT:< 15 FDEFROST W/FURNACE: YES< BACKHP TO FURNACESTAGE TIME:15 MI

Pagina 4 - INSTALLING INFINITY CONTROL

12 SYSTEM MAINTENANCE< BACKREMIND OWNER OFMAINTENANCE EVERY:12 MONTHS% USED: 50%RESET >A07033Fig. 30 -- System MaintenancePressing the right s

Pagina 5 - INITIAL POWER--UP

13Service -- Furnace Status or Gas PAC StatusThe Status screens will show all of the current operating parametersof each installed piece of equipment.

Pagina 6 - Selecting Accessories

14system. This name and phone number will appear to thehomeowner whenever a service reminder pop --up message isdisplayed (i.e. Change Filter, etc.)To

Pagina 7 - INSTALL / SERVICE MENUS

15static pressure. If it is reduced before one hour has elapsed, it willresume cooling operation. After one hour, cooling will be resumed.Dehumidify O

Pagina 8 - SETUP MENU

16SYSTEM MALFUNCTION SCREENOUTSIDE: 84_ |FAN:AUTO71_HVAC SERVICE1---800---555---1212SYSTEM MALFUNCTIONCALL TECHNICIAONA07036Fig. 34 -- System Malfunct

Pagina 9 - Setup -- Furnace

2INSTALLATIONCheck Equipment and Job SiteInspect equipment. File claim with shipping company prior toinstallation if shipment is damaged or incomplete

Pagina 10 - Setup -- Heat Pump / AC

3A03185Fig. 3 -- Infinityt ControlA03186Fig. 4 -- Recessed Mount BackplateA03187Fig. 5 -- Surface Mount BackplateA04017Fig. 6 -- Thin Decorative Backp

Pagina 11 - Setup -- System Maintenance

4A03192Fig. 10 -- Decorative Backplate AssemblyINSTALLING INFINITY CONTROLELECTRICAL OPERATION HAZARDFailure to follow this warning could result in pe

Pagina 12 - SERVICE MENUS

5be used when connecting to furnace (or fan coil). Ensure connectoris inserted properly into circuit board. (See Fig. 14.)ABCDA03193Fig. 14 -- Wire AB

Pagina 13 - CCUID01-- B

6Installer will be asked to select Accessories. Packaged Productswill be automatically identified and the Installer will be asked toselect Accessories

Pagina 14 - OPERATIONAL INFORMATION

7UV Lights InstalledThis screen will appear to select whether UV lights are installed onthe system, select YES or NO, then press right--side button to

Pagina 15 - TROUBLESHOOTING

8INSTALL/SERVICEEQUIPMENT SUMMARYINSTALLSETUPCHECKOUTSERVICESOFTWARE VERSION 1 EXIT SELECTA03200Fig. 22 -- Install / Service MenusNOT

Pagina 16 - SYSTEM MALFUNCTION SCREEN

9Reset Factory Defaults:Program Schedule:S Yes/No to reset b ack to Energy Star default Time and Tempschedules.User Settings:S Yes/No to reset the use