Carrier 52CQ Manuale Utente Pagina 10

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 44
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 9
10
HEAT PUMPS PAY THEIR
OWN WAY
Heat pump models are available at a nominal addi-
tional cost. In many locales, the payback is realized in
just a few months. Cost and payback details are pro-
vided on the next page.
Special Features
Two-Stage Indoor Thermostat:
The indoor thermostat senses the indoor temperature
and automatically turns on the electric heat to warm
the room quickly. After the desired temperature condi-
tions have been satisfied, the thermostat automatically
switches to heat pump mode. If compressor failure
occurs, the thermostat will provide backup electric
heat automatically.
Outdoor Thermostat:
During the heating cycle, the outdoor thermostat
senses outdoor coil temperature. It switches the unit to
electric heat mode when the outdoor coil temperature
is 20 F or below (approximately 35 F outdoor air tem-
perature). The thermostat switches the unit back to
heat pump mode when the outdoor coil temperature
rises above 35 F (approximately 45 F outdoor air tem-
perature), which is enough to provide heat to meet
demand. The entire operation is completely automatic.
Reversing Valve:
The reversing valve provides quiet refrigerant flow
after the unit shuts off. The valve controls the direction
of refrigerant flow for both heating and cooling func-
tions and remains energized as long as the controls are
in the heat position. When the cooling controls are
activated, the valve automatically reverses to the cool-
ing position.
Manual Compressor Override Switch:
This switch completely locks out the compressor. Note
that the compressor and heater do not operate at the
same time, thus conserving energy.
PRODUCT FEATURES AND BENEFITS (cont)
How The Heat Pump Works
In Hot Weather:
Carrier’s 52C series units provide indoor comfort in
the same manner as conventional air conditioners,
removing heat and humidity from indoor air. The heat
and humidity is released to the outdoors. Carriers
high efficiency design saves energy and reduces cool-
ing costs.
In Cool Weather:
When the outdoor coil temperature is above 20 F
(approximately 35 F outdoor air temperature), the heat
pump draws heat from outdoor air and uses it to heat
indoor air. Since heat is transferred and not produced,
Carrier’s heat pump uses less electricity and reduces
energy costs significantly.
In Sub-Freezing Weather:
When the outdoor coil temperature falls below 20 F
(approximately 35 F outdoor air temperature), the
unit automatically switches on a built-in electric
heater. The compressor stops and a blower circulates
warm air produced by the heater. When the outdoor
coil temperature rises above 35 F (approximately 45 F
outdoor air temperature), heat pump operation
resumes automatically.
Vedere la pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 43 44

Commenti su questo manuale

Nessun commento