3 --- 2
INDICATION/ REFERENCE
TROUBLE POSSIBLE CAUSES PARAGRAPH
3.3 ABNORMAL PRE SSURE CONT’D
L ow suction pressure (cont’d) L ow refrigerant charge 4.10
Inoperative Evaporator Fan Motor(s) Check
Expansion valve malfunction 3.7
Restricted air flow Check
Low evaporator air flow Blower running in reverse Check
Dirty air filter Clean
Icing of coil Clean
Relay R3, R5, R7. or R13 (black board only) defective 2.3
Fuse F3, F4, F7, F8, F11, or F12 defective 2.3
Suction and discharge pressures
equalize when operating Compressor valves defective (O5G only) 4.10*
3.4 ABNORMAL NOISE AND VIBRATIONS
3.4.1 ABNORMAL NOISE
Compressor Loose mounting bolts 4.10*
Worn bearings 4.10*
Worn or broken valves 4.10*
Liquid slugging 3.7
Insufficient oil 4.10.2*
Clutch loose or rubbing Check
CondenserorEvaporatorfan Looseordefectivebearings Check/Replace
Blade Interference Check
Blade broken or missing Check
3.4.2 ABNORMAL VIBRATION
Compressor Loose mounting bolts 4.10
Evaporator or Condenser fan Bent shaft on motor Replace motor
Blade broken or missing Check
3.5 TEMPERATURE CONTROLLER MALFUNCTION
Will not control Controller defective R eplace
Sensor defective Replace
Defective wiring Check
*Refertotheapplicablecompressor servicemanualfor additionalservicingandspecifications.For 05GBuscompressors,refertoservicemanualT---199
and parts list T---200. For Sankyo compressors,refer to manufacture literature.
Commenti su questo manuale