Copyright 2000 Carrier Corporation Form 58MXA-9PD
Product
Data
58MXA
Highly-Efficient 4-Way Multipoise
Fixed-Capacity Direct-Vent
Deluxe Condensing Gas Furnace
Series 140 & 150
Input Capacities: 40,000 thru 138,000 Btuh
4-Way Multipoise Design
Allows More Applications . . .
The model 58MXA is a must for your
product line. This high-efficiency
furnace allows more applications with
its reliable 4-way multipoise design.
The model 58MXA is available in 12
heat/airflow combinations and with the
4-way multipoise design can be
installed in upflow, downflow, or
horizontal positions covering up to 48
different applications. With the
exception of the 140 size unit, all
58MXA models can be installed in a
manufactured (mobile) home when the
optional kit is used. The furnace is
factory configured for upflow
application.
This versatile unit utilizes hot surface
ignition (HSI) which ignites the burners
directly. HSI eliminates gas waste that
typical continuous-pilot designs can
bring. Hot surface ignition provides
reliable start-up and operation.
Take a look at the control center on
model 58MXA. Control of ignition,
inducer, and blower operation is all
handled in 1 central printed circuit
board. The status indicator on the
control signals when a fault has
occurred and identifies where the
problem is. This, along with the
component test feature, makes the
58MXA one of the easiest gas furnaces
to troubleshoot.
High efficiency is achieved by
maximizing heat transfer. The model
58MXA uses 100 percent outdoor air
for combustion in a sealed-combustion
system. The result is energy-saving
efficiency, up to 95.5 percent (Pg. 12)
Annual Fuel Utilization Efficiency
(AFUE), and reduced operational noise.
The model 58MXA is one of the
quietest furnaces in the industry.
A unique feature of this unit is the
patented polypropylene-laminated
heat exchanger. This secondary heat
®
• • • •
• • • •
• • • •
ULT
RA
H
I
GH EF
F
IC
IE
NC
Y
G
A
S
F
U
R
N
A
N
C
E
®
Vedere la pagina 0
1 2 3 4 5 6 ... 19 20

Sommario

Pagina 1 - Deluxe Condensing Gas Furnace

Copyright 2000 Carrier Corporation Form 58MXA-9PD ProductData 58MXAHighly-Efficient 4-Way MultipoiseFixed-Capacity Direct-VentDeluxe Condensing Gas F

Pagina 2 - BENEFITS

10CONDENSATE TRAP1⁄2 ODINDUCER HOUSINGDRAIN CONNECTION1⁄4 ODCOLLECTOR BOX TOTRAP RELIEF PORT5⁄8 ODCOLLECTOR BOXDRAIN CONNECTION1⁄2-IN. PVC OR CPVCSCRE

Pagina 3

11Clearance to combustiblesA97609324999-201 TOP REV. BMINIMUM INCHES CLEARANCETO COMBUSTIBLE CONSTRUCTION*Mimimum front clearance for service 30inches

Pagina 4 - Model number nomenclature

12Performance dataPSC—Permanent Split CapacitorEFFICIENCY * Capacity and AFUE in accordance with U.S. Government DOE test procedures effective Novembe

Pagina 5 - Physical data

13AIR DELIVERY—CFM (With Filter)*‡•Airflow shown is for bottom only return-air supply with factory supplied 1-in. washable filter(s). • For air delive

Pagina 6 - Carrier accessories*

14Combustion-air and vent pipingMAXIMUM ALLOWABLE PIPE LENGTH (FT)See notes on pg. 15.ALTITUDE ABOVE SEA LEVEL (FT) UNIT SIZE TERMINATION TYPE PIPE

Pagina 7

15MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued* Disk usage—Unless otherwise specified, use perforated disk assembly (factory-supplied in loose parts b

Pagina 8 - Dimensions

16MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT** Pipe length (ft) specified for max

Pagina 9 - DIMENSIONS (In.)

17Electrical data* Permissible limits of the voltage range at which unit will operate satisfactorily.† Unit ampacity =125% of largest operating compon

Pagina 10 - MEDIA FILTER CABINET

18Typical installations Basement — Upflow ApplicationA93063COMBUSTIONAIR PIPEA/C COILOUTDOOR UNITVENT PIPEHUMIDIFIERGAS-FIREDWATER HEATERELECTRONICAIR

Pagina 11 - TO COMBUSTIBLE CONSTRUCTION

19COMBUSTION–AIR PIPEELECTRONICAIR CLEANERFURNACECONDENSATEDRAINREFRIGERATIONPIPINGAIR CONDITIONINGCOILAIRFLOWVENT PIPEAttic — Horizontal ApplicationA

Pagina 12 - Performance data

2 exchanger ensures that all available heat is properly transferred to the airstream and throughout the home. Using the exclusive flow-through design

Pagina 13

Carrier Corporation • Indianapolis, IN 46231 10-00Manufacturer reserves the right to discontinue, or change at any time, specifications or designs wi

Pagina 14 - See notes on pg. 15

3 NOTES: 1. The 58MXA Furnaces are for use with natural gas, but can be field converted for propane gas with a factory-authorized and listed accessor

Pagina 15

4Model number nomenclature58MXA 040Deluxe 4-Way Multipoise Fixed-CapacityDirect-Vent Condensing Gas FurnaceInput Capacity040 — 40,000 Btuh 100 — 100,

Pagina 16

5 Physical data * Capacity in accordance with U.S. Government DOE test procedures.† Gas input ratings are certified for elevations to 2000 ft. For el

Pagina 17 - Typical wiring schematic

6 Carrier accessories* * Factory-authorized and field-installed. Gas conversion kits are A.G.A./C.G.A. recognized.† For 16 and 20 airflow sizes only

Pagina 18 - Typical installations

7 ® A93086 CONCENTRICVENT A concentric vent kit allows vent and combustion-air pipes toterminate through a single exitin a roof or side wall.One pip

Pagina 19

8 17 5⁄16"24 1⁄2"27 9⁄16"TYP27 5⁄8"29 11⁄16"TYP30 13⁄16"32 5⁄8"TYP33 1⁄4"TYPCONDENSATEDRAIN TRAPLOCATION(AL

Pagina 20 - Carrier Corporation

9DOWNFLOW SUBBASE — DIMENSIONS (In.)* The plenum should be constructed 1/4 in. smaller in width and depth than the plenum dimensions shown above.FURNA