2
58MXB
and throughout the home. Using the
exclusive flow-through design, the
secondary heat exchanger reduces the
pressure drop in the furnace which leads
to lower electrical usage, an important
part of this unit’s efficiency. Carrier heat
exchangers are backed by a Limited
Lifetime Warranty. (See Warranties
section for details.)
When we put it all together, the
Comfort™ 92 combines quality and
design to bring high efficiency and
comfort. You will enjoy the versatility
and ease of installation of this unit. The
Comfort™ 92 is equipped for either left-
or right-side connections. Blower speeds
are easily adjustable with speed-taps
conveniently located on the control
center. A combustion inducer allows for
more use of 2-in. vent and combustion-air
piping, keeping installation costs low.
As with other Carrier furnaces, this
model is designed to work as a part of the
total home comfort system which in-
cludes elements for cooling, air cleaning,
humidification, ventilation, and zoning.
Comfort™ 92 FEATURES/
BENEFITS
Serpentuff
TM
— Exclusive Serpentuff
coating, a patented polypropylene
laminate is used on the secondary heat
exchanger.
Power Heat™ Igniter
— Carrier’s
unique SiN igniter is not only physically
robust but it is also electrically robust. It
is capapble of running at line voltage and
does not require complex voltage
regulators as do other brands. This unique
feature further enhances the reliability of
Comfort™ 92 gas furnace and continues
Carrier’s traditoin of tecnology
leadership and innovation in providing a
reliable and durable product.
ComfortFan™
— Improves comfort all
year long by allowing the homeowner to
select different fan speeds during contin-
uous fan operation to achieve more or
less airflow. This is done right at the
thermostat.
SmartEvap™
— This feature allows
your system to reduce summertime
humidity levels by nearly 10% over
standard systems.
Media Filter Cabinet
— Enhanced in-
door air quality in your home is made
easier with our media filter cabinet—a
standard accessory on all Deluxe fur-
naces. When installed as a part of your
system, this cabinet allows for easy and
convenient addition of a Carrier high-
efficiency air filter.
Control Center
— Microprocessor
controls sequencing and furnace
operation. Equipped with a component
test feature and status indicator light to
assist in troubleshooting. Micro-
processor blower control times blower
start after main burners ignite to eliminate
cold air blowing into rooms.
Warranties
— Limited Lifetime
Warranty on the heat exchangers for the
lifetime of original owner in single family
residence; 20 years in other residential
and commercial applications. Five-year
Limited Warranty on entire unit. Contact
your dealer for details.
Direct or Non-direct Venting
— The
Comfort™ 92 can be installed as a 1
pipe/Non-Direct vent (except 140 size
unit and in manufactured/mobile home
installations) or 2 pipe/Direct vent fur-
nace. This provides added flexibility to
meet diverse installation needs.
Insulated Blower Compartment
—The
acoustical insulation reduces air and
motor noise to promote quiet operation.
Combustion Products Venting
The combustion-air and vent pipes can
terminate through a side wall or through
the roof when used with a factory-
authorized vent termination kit.
Insulation —
Foil-faced insulation in
heat exchanger section of the casing
minimizes heat loss.
Bottom Closure
— Factory-installed for
side return; easily removable for bottom
return.
Filter
— Cleanable filter with retainer is
standard.
Blower Access Panel Switch
— Shuts
off all 115-v power through furnace
components whenever blower access
panel is opened.
Casing
— One piece, seamless
wrap-around construction of heavy,
galvanized steel resists corrosion.
Adjustable Blower Speed
— For
precise airflow selection of heating or
cooling operation.
Monoport Burners
— The burners are
finely tuned for smooth, quiet
combustion plus economical gas usage.
Slow Opening Redundant Gas Valve
— Shuts off gas to burners if 1 of the
valves fails to close completely for any
reason. The slow opening feature reduces
start-up noise from rapid ignition.
Quality Registration
— The Comfort™
92 is engineered and manufactured under
an ISO 9001 registered quality system.
Certifications
— The Comfort™ 92
Model units are CSA (A.G.A. and
C.G.A.) design certified for use with
natural and propane gases. The furnace is
factory-shipped for use with natural gas.
A CSA (A.G.A./C.G.A.) listed gas
conversion kit is required to convert
furnace for use with propane gas. The
efficiency is GAMA efficiency rating
certified. The Comfort™ 92 meets
California Air Quality Management
District emission requirements. Except
for the 140 size unit, all Comfort™ 92
models can be installed in a
manufactured (mobile) home when the
optional kit is used in direct vent (2-pipe)
application. Refer to Vent Table, for
elevation limitations.
A92505
HEAT EXCHANGERS
BLW
NUETRAL
STATUS CODE LED
SEC-2 SEC-1
EAC-2 L2
FUSE 3-AMP
0.5 AMP@24VAC
HUM
TEST/TWIN
Y1 DHUM G COM W/W1 Y/Y2 R
24V
PLT
120 180
90 150
BLOWER OFF-DELAY
PLT 1
COOL HEAT
SPARE-1 SPARE-2
FAN
EAC-1
1-AMP@
115VAC
PR-1
L1
PL2 1
24-V THERMOSTAT
TERMINALS
3-AMP FUSE
LED OPERATION &
DIAGNOSTIC LIGHT
115-VAC(L2)NEUTRAL
CONNECTIONS
COOL
HEAT
SPARE-1
SPARE-2 FAN
BLOWER SPEED
SELECTION TERMINALS
EAC-1 TERMINAL
(115-VAC 1.0 AMP MAX.)
115 VAC (L1) LINE
VOLTAGE CONNECTION
PL2-HOT SURFACE
IGNITER & INDUCER
MOTOR CONNECTOR
PL1-LOW VOLTA
GE MAIN
HARNESS CONNECTOR
TRANSFORMER 24-VAC
CONNECTIONS
HUMIDIFIER TERMINAL
(24-VAC 0.5 AMP MAX.)
TWINNING AND/OR
COMPONENT TEST
TERMINAL
BLOWER OFF-DELAY
A02142
CON
TR
O
L
C
E
N
TER
A02172
INDUCER ASSEMBLY
Vedere la pagina 1
1 2 3 4 5 6 7 ... 21 22

Commenti su questo manuale

Nessun commento